Model NO.: MPCT-250TS
Noise Level: Low
Application Fields: Industrial
Certification: CE, CTI
Condition: New
Cooling Capacity: 58kw ~ 1744kw
Flow Rate: 10m3/H ~ 300m3/H(Customized)
Air Capacity: 6400m3/H ~ 384000m3/H
Tower Body Material: HDG/Stainless Steel
Filler Material: Fire Retardant PVC
Fan Material: Aluminium Alloy
Waterproof Pump: IP55
Drift Loss: <=0.001%
Net Weight: 640kg ~ 9000kg
Running Weight: 1730kg ~ 21800kg
Trademark: MAIPT
Transport Package: in Bulk(20′~40′ Container)
Specification: 100MT-5000MT
Origin: China
HS Code: 84195000
Model NO.: MPCT-250TS
Noise Level: Low
Application Fields: Industrial
Certification: CE, CTI
Condition: New
Cooling Capacity: 58kw ~ 1744kw
Flow Rate: 10m3/H ~ 300m3/H(Customized)
Air Capacity: 6400m3/H ~ 384000m3/H
Tower Body Material: HDG/Stainless Steel
Filler Material: Fire Retardant PVC
Fan Material: Aluminium Alloy
Waterproof Pump: IP55
Drift Loss: <=0.001%
Net Weight: 640kg ~ 9000kg
Running Weight: 1730kg ~ 21800kg
Trademark: MAIPT
Transport Package: in Bulk(20′~40′ Container)
Specification: 100MT-5000MT
Origin: China
HS Code: 84195000
Power Saving Wet FRP Cooling Tower for Industry

Power Saving Wet FRP Cooling Tower for Industry
 
 BRIEF DESCRIPTION WWW.MAIPT.LTD/


The MPCT-TD/TS series use a combination of secondary heat exchange coil where air and water flow in the same direction and PVC filler, which enables efficient heat

transfer. As the air and spray water flow through the coil in the same direction, the spray water can cover the surface of the coil to the maximum extent to ensure that the

surface of the coil is completely wet. Compared to the structure of air and water flowing reversely, the formation of dry spots and scale on the coil wall is greatly reduced.


Both of fans and pumps adopt high quality bearings without other wear parts.The fan adopts a direct connection structure so that there is no rotational loss caused by the

pulley structure, and the noise is small and the failure rate is low.


INNER STRUCTURE AND MAIN PARTS INTRODUCTION

Power Saving Wet FRP Cooling Tower for Industry

 
 FEATURES & MATERIALS WWW.MAIPT.LTD/
 
Features   Materials
Space-saving, Light Metal Structure

Cooling
System
Cooling Coil SUS304 Tube (DN18mm; Thickness: 0.8 mm), anti-freezing type
Optimized structural design and using steel structure make the floor area reduced greatly, the running weight is also greatly reduced Cooling Fin PVC Vacuum plastic, on-line lamination process
Spraying Pipe Corrosion resistant PVC
Good Corrosion Resistance Sprayer ABS, uniform water distribution, no dead corner, no dry point
Tower body material is FRP with good corrosion resistance, the light stabilizer in resin has good anti-aging properties and won't fade. Spray Pump Cast iron material, Siemens motor, High flow and low pump head
Circulating
System
Buffer Tank SUS304 material; Usage: Buffering, Exhausting, Pressure maintaining
Durable and Long Lasting Water Pump One used and the other is backup, controlled by frequency converter
The reinforced fiberglass without corrosion, reducing maintenance costs. All tower supports are made of thick steel and treated with hot dip zinc.
Fan Power
System
Fan Extruded aluminum alloy (airfoil type); high strength, corrosion resistance
Motor (IP55.F) Special for cooling tower, fully closed, low noise, maintenance-free
Combined type Design Bearing Bearing steel, NSK/SKF
It's free to choose multiple cooling tower combined use as needed. The accessories are portable and easy to transport and install. Dehydrator Original PVC sheet from FORMOSA PLASTICS, water saving.

Tower
Body
Front Panel Al-Zn alloy coated steel sheet, high intensity, corrosion resistance
Energy-saving Structural Steels Hot Dip Galvanized material, three-times preservative treatment
Low wind resistance and heat dissipation filler combined with the unique streamlined design of the ventilator, save power consumption greatly. Bottom Frame U-steel after special preservative treatment, long-lasting
Low Noise Standard Parts Hot Dip Galvanized material, corrosion resistance
Large size streamlined designed fan blade, combined with low speed running to make fan especially quiet Sealing Tape Butyl rubber, reliable sealing
Electric Control Cabinet Thickness: 1.5mm; Powder coating, LG contactor
Remark: The materials of the above different parts are subject to customization accoring to unique requirements.

 
 TECHNICAL SPECIFICATION WWW.MAIPT.LTD/
 
Model Cooling Capacity Overall Dimension Cooling Fan Pump Pipeline Size Weight
Water Flow Thermal Power L W H Blade Power Air Capacity Power In/Outlet Overflow Drain Make up N.W. R.W.
m3/h kw mm mm mm mm kw m3/h kw mm mm mm mm kg kg
MPCT-TD series Closed Type Counter Flow Cooling Tower
MPCT-10TD 10 58 2100 1500 2480 Ф700 0.55 6400 0.55 DN65 DN25 DN25 DN25 640 1730
MPCT-15TD 15 87 2100 1500 2700 Ф750 0.75 9600 0.55 DN65 DN25 DN25 DN25 710 1880
MPCT-20TD 20 116 2100 1500 2950 Ф800 0.75 12800 0.55 DN80 DN25 DN25 DN25 810 1920
MPCT-30TD 30 174 2300 1800 3080 Ф800 1.5 19200 0.75 DN80 DN25 DN25 DN25 920 2320
MPCT-40TD 40 232 2800 1800 3130 Ф1000 1.5 25600