Model NO.: MPCH
Heating Temp. Range: +5 to 98 Degree
Cooling Tempe. Range: -15 to 15 Degree
Emp. Control Accuracy: Within +/- 0.1 Degree
Heating Type: Circulating Heating
Cooling Method: Direct Cooling
Guarantee Period: 15 Months
Lifetime: More Than 5 Years
Trademark: MAIPT
Transport Package: Wooden Case as Usual
Specification: 1880*914*1785mm
Origin: China
HS Code: 8419899090
Model NO.: MPCH
Heating Temp. Range: +5 to 98 Degree
Cooling Tempe. Range: -15 to 15 Degree
Emp. Control Accuracy: Within +/- 0.1 Degree
Heating Type: Circulating Heating
Cooling Method: Direct Cooling
Guarantee Period: 15 Months
Lifetime: More Than 5 Years
Trademark: MAIPT
Transport Package: Wooden Case as Usual
Specification: 1880*914*1785mm
Origin: China
HS Code: 8419899090
Dual Zones Chiller&Heater Mold Temperature Controller Unit

MPCH series Chiller&Heater Mold Temperature Controller Unit has two temperature control zones, one is for heating from +5 to 98 Degree and the other is for cooling from -15 to 15 Degree.


FEATURES:                         
              
 Original imported compressor
 Switchover of heating power
 Explosion-proof device ( Optional )
 System pressure&Functional test before shipping
 Copper tube adopt oxygen-free welding to reduce oxides
 Control mode : imported microcomputer or ( Optional ) PLC 
 SUS304 integrated pipelines for less pipe resistance and rust
 RS485 communication for automated management ( Optional )
 High-efficiency evaporator and condenser to save energy more than 30%
 Customization for muti-points temperature control unit is acceptable
 Customizable horse power and heating/cooling power for water pump ( Optional )
 Original imported American and European compenents to extend using life
 Perfect safety protections, faults display, easy maintence even without professional staff

      
SPECIFICATION TABLE FOR MPCH SERIES
 
Item MPCH-3W(A) MPCH-5W(A) MPCH-10W(A) MPCH-15W(A) MPCH-20W(A) MPCH-30W(A) MPCH-40W(A) MPCH-50W(A)
Cooling Capacity KW 50HZ 9.59 15.91 31.83 50.14 67.14 99.19 129.06 153.91
Kcal/hr 50HZ 8251 13690 27370 43120 57748 85303 110984 132359
Power Supply 3N-380V/415V 50HZ/60HZ
Compressor   Type    Hermetic Scroll or Piston
Power KW 2.25 3.75 3.75*2 5.5*2 7.5*2 7.5*3 7.5*4 7.5*5
Cooling Water Flow M3/hr 2.06 3.42 6.85 6.85 14.44 21.32 27.74 33.09
Pressure Drop M3 28 34 34 34 38 36 35 42
Inlet/Outlet Pipe Size G3/4'' G1-1/2'' G1-1/2'' G2'' G2 G2-1/2'' G3'' G3''
Chilled Water Flow M3/hr 1.65 2.74 5.74 5.74 11.55 17.06 22.19 26.48
Pressure Drop M3 0.038 0.065 0.188 0.285 0.285 0.405 0.61 0.61
Inlet/Outlet Pipe Size G3/4'' G1'' G2'' G2'' G2-1/2'' G2-1/2'' G3'' G3''
Chilled Water
Pump
Power KW 0.375 0.75 1.5 1.5 2.2 4 4 4
  Pressure Kpa 200 200 205 205 220 240 240 240
Hot Water
Pump
Power KW 0.75 0.75 1.5 1.5 1.5 2.2 3.75 3.75
  Pressure Kpa 200 200 205 205 205 220 240 240
Air Flow M3/hr 6 6 12 15 18 24 36 48
Dimension L*W*H CM 83*46*102 108*58*123 130*61*14.5 167*75*160 188*91*178 213*94*178 240*100*178 240*107*198
Weight  KG 151 220 312 400 440 690 750 1000
REMARK: Above configurations are just for reference, parts brand and Qty would be changed accoridngly.


AFTER-SALE SERVICE COMMITMENT

1- Technical Documents            
        
   All labels on machines and lay-out drawings, Electrical diagram, User Manual, will be in English. MAIPT should send all necessary files to the buyer since the third week since project execution. All documents in hard copies should be also shipped with machines together.

2- Arrangement for Installation & Testing Work      
             
a. After all machines are delivered to customer's factory; Buyer is responsible for all preparation work, e.g. electricity supply, water supply, labors and cranes, etc.
           
b. MAIPT will prepare for visa application for their engineers, who are responsible fo guide of machine installation and testing at the Buyer's factory.

c. The Buyer will buy the round-trip air ticket for Engineer if visa application is approved. The buyer is also responsible to bear expenses generated, e.g. visa formalities, meals, accommodation and allowance of USD100 per day for each engineer.

d. Engineer will give free training lessons to labors in buyer's factory.  
                 
3- Quantity and quality guarantee  
                 
a. Quantity/Quality Discrepancy to destination port during transportation:
   In case of quality/quantity discrepancy to destination port in transportation, customer should file claim within 30 days after the arrival of the goods at port of destination. TRUEWARM will be responsible for any discrepancy of the goods caused by shipping  company and other transportation organization and/or post office.

b. 12 months since date of bill of lading.
   During this guarantee period, MAIPT will provide spare parts without any charge in case of quality caused by us. If the malfunctions are caused by your incorrect operations, MAIPT will provide the buyer spare parts at cost price.

c. Long-term service:
   MAIPT will charge the buyer cost price of spare parts beyond one year and provide long-term  technical guide.
  Dual Zones Chiller&Heater Mold Temperature Controller Unit

MPCH series Chiller&Heater Mold Temperature Controller Unit has two temperature control zones, one is for heating from +5 to 98 Degree and the other is for cooling from -15 to 15 Degree.


FEATURES:                         
              
 Original imported compressor
 Switchover of heating power
 Explosion-proof device ( Optional )
 System pressure&Functional test before shipping
 Copper tube adopt oxygen-free welding to reduce oxides
 Control mode : imported microcomputer or ( Optional ) PLC 
 SUS304 integrated pipelines for less pipe resistance and rust
 RS485 communication for automated management ( Optional )
 High-efficiency evaporator and condenser to save energy more than 30%
 Customization for muti-points temperature control unit is acceptable
 Customizable horse power and heating/cooling power for water pump ( Optional )
 Original imported American and European compenents to extend using life
 Perfect safety protections, faults display, easy maintence even without professional staff

      
SPECIFICATION TABLE FOR MPCH SERIES
 
Item MPCH-3W(A) MPCH-5W(A) MPCH-10W(A) MPCH-15W(A) MPCH-20W(A) MPCH-30W(A) MPCH-40W(A) MPCH-50W(A)
Cooling Capacity KW 50HZ 9.59 15.91 31.83 50.14 67.14 99.19 129.06 153.91
Kcal/hr 50HZ 8251 13690 27370 43120 57748 85303 110984 132359
Power Supply 3N-380V/415V 50HZ/60HZ
Compressor   Type    Hermetic Scroll or Piston
Power KW 2.25 3.75 3.75*2 5.5*2 7.5*2 7.5*3 7.5*4 7.5*5
Cooling Water Flow M3/hr 2.06 3.42 6.85 6.85 14.44 21.32 27.74 33.09
Pressure Drop M3 28 34 34 34 38 36 35 42
Inlet/Outlet Pipe Size G3/4'' G1-1/2'' G1-1/2'' G2'' G2 G2-1/2'' G3'' G3''
Chilled Water Flow M3/hr 1.65 2.74 5.74 5.74 11.55 17.06 22.19 26.48
Pressure Drop M3 0.038 0.065 0.188 0.285 0.285 0.405 0.61 0.61
Inlet/Outlet Pipe Size G3/4'' G1'' G2'' G2'' G2-1/2'' G2-1/2'' G3'' G3''
Chilled Water
Pump
Power KW 0.375 0.75 1.5 1.5 2.2 4 4 4
  Pressure Kpa 200 200 205 205 220 240 240 240
Hot Water
Pump
Power KW 0.75 0.75 1.5 1.5 1.5 2.2 3.75 3.75
  Pressure Kpa 200 200 205 205 205 220 240 240
Air Flow M3/hr 6 6 12 15 18 24 36 48
Dimension L*W*H CM 83*46*102 108*58*123 130*61*14.5 167*75*160 188*91*178 213*94*178 240*100*178 240*107*198
Weight  KG 151 220 312 400 440 690 750 1000
REMARK: Above configurations are just for reference, parts brand and Qty would be changed accoridngly.


AFTER-SALE SERVICE COMMITMENT

1- Technical Documents            
        
   All labels on machines and lay-out drawings, Electrical diagram, User Manual, will be in English. MAIPT should send all necessary files to the buyer since the third week since project execution. All documents in hard copies should be also shipped with machines together.

2- Arrangement for Installation & Testing Work      
             
a. After all machines are delivered to customer's factory; Buyer is responsible for all preparation work, e.g. electricity supply, water supply, labors and cranes, etc.
           
b. MAIPT will prepare for visa application for their engineers, who are responsible fo guide of machine installation and testing at the Buyer's factory.

c. The Buyer will buy the round-trip air ticket for Engineer if visa application is approved. The buyer is also responsible to bear expenses generated, e.g. visa formalities, meals, accommodation and allowance of USD100 per day for each engineer.

d. Engineer will give free training lessons to labors in buyer's factory.  
                 
3- Quantity and quality guarantee  
                 
a. Quantity/Quality Discrepancy to destination port during transportation:
   In case of quality/quantity discrepancy to destination port in transportation, customer should file claim within 30 days after the arrival of the goods at port of destination. TRUEWARM will be responsible for any discrepancy of the goods caused by shipping  company and other transportation organization and/or post office.

b. 12 months since date of bill of lading.
   During this guarantee period, MAIPT will provide spare parts without any charge in case of quality caused by us. If the malfunctions are caused by your incorrect operations, MAIPT will provide the buyer spare parts at cost price.

c. Long-term service:
   MAIPT will charge the buyer cost price of spare parts beyond one year and provide long-term  technical guide.
 

Spin-On Oil Filter Element-Simple removal by spinning off and replacing the element. Manufactured of synthetic, paper, metal mesh or cloth, with a micron rating which varies based on manufacturer specifications.
The proper selection and use of compressed Air Filters will prevent many short and long term problems with your compressed air equipment and systems and save you substantialy in down-time and component replacement costs over the life of your compressed air system.
Oil Filters present the second barrier of protection. These are usually rated at 10 to 20 microns. Filter Material is also paper or synthetic, and can be surface loading or depth loading.(contaminants enter the filter media and are trapped within the depth of the media, rather than only on the surface.)

Canister(Cartridge) Oil Filter Element-This consists of an element inside a metal canister. The canister must be opened, and the new filter installed inside the cavity. This element may be a variety of materials(metal mesh, synthetic, paper, or cloth) and will be manufactured with micron ratings compatible to the OEM specifications.Sinofiltec offers branded and high quality replacement filters for all domestic and international compressor OEMs. 

air compressor oil filters

compressor oil filter element

air compressor oil filter element

Replacement Air Compressor Oil Filter

screw compressor oil filter cartridge


   

Compressor Oil Filters

Compressor Oil Filters,Air Compressor Oil Filter

Henan Sinofiltec Technology Co.,Ltd , https://www.airfilters.pl

Posted on