When running dosing system should pay attention to what important matters?

When running dosing system, pay attention to the following points:
A. dosing pressure

B. Stroke frequency

C. Suction height

D. Altitude

E. Corrosive chemicals

When metering pump outlet for atmospheric pressure, what measures can be taken to improve the pump repeat measurement accuracy?

Installing the valve spring at the metering pump discharge valve improves repeat metering accuracy, but the most effective improvement is the installation of a backpressure valve at the end of the line.

How to adjust the back pressure valve?

1. Never exceed the maximum working pressure of the metering pump.

2. When the dosing pump has pressure on the suction side, the pressure on the discharge side of the pump must be at least 1 bar higher than the pressure on the suction side.

How to choose the right pulse damper volume?

By multiplying the metering capacity (ml) per stroke of the metering pump (ml) by 26, the minimum volume (ml) of the pulsation dampener required to reduce the 90% pulsation can be obtained.

How to set the pressure relief valve?

The pressure of the safety valve can be adjusted within the range of the rated working pressure of the metering pump and the maximum working pressure of the metering pump should not be exceeded. The safety valve is designed to prevent over-pressurization of the metering pump. For example, if the maximum working pressure of the metering pump is 3 bar, the relief valve pressure should be set at 3 bar, or lower to ensure proper operation of the metering pump. Overpressure is one of the major causes of dosing pump damage.

If the delivery of liquid is not water, how to calculate the suction height?

Divide the metering pump's nominal aspiration height by the specific gravity of the metering liquid.

Under what circumstances with self-irrigation suction?

Self-priming aspiration can be applied if:

1.Measurement of liquid volatile;

2. Measuring the proportion of liquid larger;

3. When higher stroke frequency is required;

4. Metering pump work in high altitude areas;

5. In the field of application requires a larger tank, and rely on the self-priming pump is not feasible.

Could you give me some advice on pump head selection? What are some common problems with chemical pump head / seal corrosion and should I avoid?

The usual problem when it comes to metering pump heads is the presence of acid, chlorine, fluoride and hydrogen peroxide. Due to the different drug concentration and operating temperature, it is difficult to determine the specific pump head material. When measuring fluoride, we recommend using a Viton® sealed PVC pump head. For most chlorination applications, it is best to use an EPDM sealed NP (plexiglass) pump head. For the hydrogen peroxide mixture can only be measured PTFE PTFE sealed PTFE pump head or stainless steel pump head. The measurement of concentrated hydrochloric acid is usually Viton® sealed plexiglass pump head. Concentrated sulfuric acid can be selected PTFE sealed PTFE pump head. The manufacturer of the chemical gives advice or consult the ProMinent® Chemical Preservation Chart to determine the compatibility of the chemical with the contact material.

When measuring the liquid in the pump head, which factors must be considered?

The main factors to be considered are the viscosity, specific gravity, vapor pressure and temperature of the liquid.

Boiler Production Cutting Machine

The CNC plasma cutting machine is a desktop gantry structure. The whole work surface of the machine adopts the integral rim structure, which has the characteristics of stable and reliable operation and long service life. The model adopts optical axis linear guide and bilateral drive. It can realize the cutting of any metal materials according to any pattern, and it is suitable for the rapid CNC cutting of carbon steel plates, aluminum plates, copper plates, stainless steel plates and other workpieces with medium and thin plates. The effect is good, no dross and burrs are used; Directly use Wentai software or AutoCAD drawing software to directly draw graphics, without conversion, direct cutting, and can be simple to discharge, the workpiece is set side by side. At the same time, it also solves the problem that the thin plate and the thick plate cannot be compatible. This machine comes standard with plasma cutting method, equipped with arc-pressure automatic height-adjusting system and torch anti-collision system. It is also equipped with a set of water spray cooling device to reduce the thermal deformation of thin plate cutting; this type of equipment is cutting and cutting equipment for sheet metal processing industry and ventilation pipe industry.